of 22
Steam Generator Installation and Operating Man ual STEAMPR O TM SteamPr o.
IMPOR T ANT SAFETY INFORMA TION READ ALL INST ALLA TION INSTR UCTIONS Jacuzzi Whirlpool Bath does not recommend prolonged periods of use of the steamer . Prolonged use of the steam system can raise e xcessively the internal human body temperature and impair the body’ s ability to regulate its internal temperature (hyper thermia).
Contents Installation of Steam Generator Specifications ______________________________________________________________________________ 1 How to Select Gener ator Size and Electrical Requirements _____.
Ho w to Select Generator Siz e Step 1. Determine cubic footage of steam enclosure: multiply LENGTH inches x WIDTH inches x HEIGHT inches to find cubic inches. Divide cubic inches by 1728 to determine cubic feet. Step 2. Find steam enclosure size within the ranges shown on the chart for the supply voltage (240 VAC or 208 VAC).
Locating the Steam Generator The steam generator must be installed upright and le vel. The steam generator m ust be located within a 25 f oot maximum steam line run to the steam head AND within the 25 f oot control wire length to an y controls. It may stand attached to a horizontal base or to a wall.
Plumbing Instructions and Cautionar y Notes on Installation Minerals in the water or poor water quality can shorten the life of the steam generator or cause erratic operation if the tank is not drained regularly. Drain the tank frequently. Jacuzzi Whirlpool Bath also strongly recommends purchasing and installing the optional drain down valve.
INST ALLA TION STEAM UNIT TO BE LEVEL AND UPRIGHT SEE P AGE 5 FOR SUGGESTED LOCA TIONS W A TER SUPPL Y WITH SHUT-OFF V AL VE (3/8 OR 1/2 INCH COPPER) TO STEAM HEAD SEE P AGES 8 AND 9 FOR STEAM HEAD PLUMBING AND INST ALLA TION FOR V ARI- OUS W ALL SURF ACES.
INST ALLA TION Steam Head Installation f or V arious W all Surfaces Jacuzzi Whirlpool Bath recommends that the steam shield be used for all steam head installations. The steam shield must be installed if the steam head is located on acrylic (or other plastic) wall surfaces or above a bath rim.
INST ALLA TION 10 kW Steam Generator with T wo Steam Heads Two steam heads may be installed with the Model E210000 Steam Generator, if desired. This will reduce the sound level of the exiting steam and will provide more even steam distribution and less heat concentration in larger steam enclosures.
1. Apply thread compound sparingly to male threads on fitting A . (Keep thread compound from entering the valve.) 2. Using a backup wrench to hold fitting A, thread valve assembly onto fitting and tighten. Valve outlet must point as shown. 3. Make certain power is disconnected .
INST ALLA TION Steam Cont r ols — A v ailable Installation Methods Various control packages are available for use with the steam generator. The following instructions (A – C, pages 12 - 16) describe the different installations. Select one of the following control options: A.
INST ALLA TION APPLY SEALANT (100% SILICONE CAULK) 1-3/4" DIAMETER HOLE IN FINISHED WALL (OPTIONAL NUT INSTALLATION IF BACK OF WALL IS ACCESSABLE) A. STEAM CONTR OL BY 30 MINUTE LO W V OL T A GE ON/OFF CONTR OL. THIS LOW VOLTAGE CONTROL CAN BE LOCATED INSIDE OR OUTSIDE THE STEAM ENCLOSURE 1.
INST ALLA TION GENERAL INSTRUCTIONS FOR TEMPERA TURE CONTROL MODELS 1. Contr ol Cable Rough-in The low v oltage control can be mounted up to 25 feet from the generator either inside or outside the steam room, also see #6 optional secondary digital generator control.
INST ALLA TION 5. INST ALL GENERA T OR CONTR OL The low v oltage control can be mounted directly to a finished wall either inside or outside the steam room. Using a 2" hole saw , drill a hole in the finished wall where the control is to be mounted (the control cable should already be roughed-in to this location).
OPERA TION B. 30 MINUTE TEMPERA TURE CONTROL The 30 minute temperature control f eatures a 30 minute press on timer lighting up the word "STEAM" and a thermostatic control preset to reach 120 degrees F ahrenheit. The digital control can be mounted either inside or outside the steam room.
OPERA TION C. DIGIT AL TIME AND TEMPERA TURE CONTROL The digital control f eatures an adjustable 60 minute time and temperature control with digital display . The actual room temperature and time remaining are alternately display ed ev er y 5 seconds.
SER VICE Description of SteamPr o Steam Generator The SteamPro series generator is the latest in moder n steam generator design. The SteamPro steam generator uses a printed circuit assembly to monitor and control all the equipment needed to produce steam.
TROUBLESHOOTING There are no user ser viceable par ts in the Generator . All repair should be performed by a qualified service person. F or additional assistance or the f actor y authorized ser vice person nearest you call the Service Depar tment at 1-800- 363-0251.
TROUBLESHOOTING S M O T P M Y SS E S U A C E L B A B O R PN E K A T E B O T N O I T C A . " N O " l o r t n o C ) n o t h g i l l o r t n o C ( . m a e t s t ' n o w t i n U t i l m a e t S : e t o N r o y l i d a e t s y l r e p o r p p m e T / e m i T l a t i g i D n o d e y a l p s i d y a l p s i D .
WIRING DIAGRAM PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. USE INSTALLATION INSTRUCTIONS SUPPLIED WITH PRODUCT. Jacuzzi Whirlpool Bath has obtained applicable code (standards) listings generally available on a national basis for products of this type.
J acuzzi Whirlpool Bath, warrants that its Steam Generators (w arranted products) are free of man ufacturing def ects both as to workmanship and material for 5 y ears and it will replace or repair def ective par ts or equipment f or the period of time and in accordance with the conditions set for th below .
6. Procedure. Requests f or repair or replacement, a retur n author ization number , or warranty inf or mation should be directed to AMEREC by calling toll-free 1-800-363-0251 or b y writing to AMEREC, 17683 128th Place N.E., W oodinville , W A 98072.